Publishing PDFs should be simple, but the number of steps required can make it unnecessarily time-consuming. Plot Pilot reduces-or even eliminates-those steps. Plot Pilot provides profile-driven Revit sheet publishing with reusable configurations, assigned or prompted workflow modes, output organization, PDF assembly, and naming presets. Make a simple task simple again.
Version 1.0.0PDF exportEight-step PPC workflowPersonal + licensed plans
Plot Pilot Hero Image
Eight configurable steps
One button, eight saved publishing decisions.
Plot Pilot can save every decision behind a publish. Each of the eight workflow steps can stay assigned for a one-click button, or switch to prompted mode when runtime flexibility is needed.
Saved ribbon buttonCoordination
Saved ribbon buttonReview
Saved ribbon buttonSD Set
Saved ribbon buttonDD Set
Saved ribbon buttonIFP Set
Saved ribbon buttonCheckset
Sheet List Schedule
Use assigned Sheet Lists
Step 1Prompt for the Sheet List
Sheets
Publish assigned Sheets
Step 2Prompt for the Sheets
Location
Save the PDF to assigned location
Step 3Prompt for location
Folder
Save the PDF to assigned folder presets
Step 4Prompt to create or use existing folder
PDF Output
Create a sheet or compile the sheets together
Step 5Prompt for single or combined sheets
File Naming
Set a naming standard and parameter
Step 6Prompt for a file name
Processing
Set the color and other parameter
Step 7Prompt for color and other PDF processing parameter
File Handling
Overwrite any existing files
Step 8Prompt how to handle existing files
FAQ
Plot Pilot questions answered.
PPC setup, ribbon assignments, and common issues across all eight publishing steps.
How do I create my first Plot Pilot Configuration (PPC)?▼
Open Plot Pilot Config, activate any PPC name from the dropdown menu, press Duplicate button , give it a clear name, and work through Steps 1–7. Choose Prompted options when the user should decide during publishing, or Assigned options when the saved button should run with preset values. Save the PPC when every required step is complete.
How do I edit, duplicate, rename, or delete an existing PPC?▼
Open the PPC in Plot Pilot Config and use the titlebar actions. Edit changes the selected configuration, Duplicate creates a separate copy, Rename changes the PPC name, and Delete removes it after the inline confirmation. Use Save to commit changes; unsaved changes are marked with an asterisk.
How do I assign or edit a PPC ribbon button?▼
In the PPC button settings, choose the button type, two-line label when applicable, tooltip, icon, and spreadsheet-style ribbon position. Full-height buttons use Column A, Column B, and so on. Stacked controls use positions such as Stack Column A1, A2, and A3. Plot Pilot Config remains the final control in the panel.
Why did my ribbon button not appear or update after saving?▼
Save the PPC, then use Reload Ribbon so Revit rebuilds the Plot Pilot panel from the current saved configurations. Confirm that the PPC has a valid button type and position and that no other PPC is occupying the same position. If the ribbon is not available in the current Revit session, restart Revit once and check the saved PPC again.
Step 1 — Why is Plot Pilot still prompting for a Sheet Index?▼
For a fully assigned workflow, select Assigned Sheet Index and choose the intended Revit Sheet List. Review the variation value as well: a prompt-style or wildcard variation can still require a runtime choice. If the saved Sheet List no longer exists in the model, edit the PPC and assign a current list.
Step 2 — Why are the wrong sheets shown, or no sheets available?▼
The sheet scope is evaluated after the Sheet Index and variation. Verify whether the PPC is set to All matching sheets, Prompt for sheets, or Specific assigned sheets. Specific assignments must still exist in the active model, while prompted results depend on the Sheet List and variation resolved in Step 1.
Step 3 — Why is the PDF output location wrong or unavailable?▼
Check whether Location is project-relative, user-selected, or an absolute path. Project-relative output requires a valid saved project path. Confirm that the target folder and network drive are accessible to the current user. Cloud models are not supported as a local project-relative output source, so use a selected or absolute accessible folder instead.
Step 4 — Why is my assigned folder or folder preset missing?▼
Confirm that the PPC is using the intended Assigned or Prompted folder mode. An assigned preset must still exist in the configured presets location. A prompted folder must be present in the PPC bucket or entered during the runtime wizard. Recreate a deleted default preset or select another available folder rule.
Step 5 — How do I fix separate or combined PDF output issues?▼
Review the saved PDF Output mode. Separate creates individual sheet PDFs; combined modes assemble matching sheets according to the configured grouping. Make sure the selected sheets can be exported and that the output folder and naming formula do not produce conflicting file paths.
Step 6 — Why is the PDF name incomplete, invalid, or not using my preset?▼
Open the assigned naming preset and verify the formula order. System, Custom, and Separator variables must be arranged in the desired sequence, and dirty presets must be saved before the PPC uses them. Check custom values for Windows-invalid filename characters and make sure the final formula produces a usable name for every selected sheet or combined set.
Step 7 — Why does the exported PDF appearance not match my settings?▼
Verify whether Processing is set to Show PDF Processing Options or Assigned PDF Processing Options. Review Color, Black Lines, or Grayscale; Vector or Raster processing; raster quality; and the hide options for reference planes, view tags, scope boxes, and crop boundaries. Prompted settings can be changed by the user at runtime, while assigned settings run as saved.
Build the publishing button your project needs.
Start with Personal, test the full workflow with a 15-day Trial, or activate Pro or Team access.
Your browser or security software may warn about or block this installer because it is an uncommon or unfamiliar file. Depending on your settings, the download may require confirmation.
Windows or your security tools may also show a warning when you run the installer. Continue only if you downloaded it from BIMGrove and intended to install this BIMGrove Revit add-in.
✓
Support request sent.
Your support request was submitted successfully. BIMGrove support will follow up using the email you provided.